Aplisens Electromagnetic Flowmeter PEM-500 Series
Introduction – Aplisens Electromagnetic Flowmeter PEM-500 Series
The Aplisens Electromagnetic Flowmeter PEM-500 Series is designed for accurate measurement of conductive liquids with a minimum conductivity of 5 µS/cm. Operating on the electromagnetic induction principle, it provides precise and stable readings of flow rate and total volume in both directions. Its compact, sealed design with no moving parts ensures maintenance-free operation and undisturbed flow of the measured medium.
Engineered for versatility, the PEM-500 Series is suitable for pure, viscous, and chemically aggressive liquids. It is widely used in water and wastewater treatment, chemical processing, food production, and thermal energy plants. The instrument’s robust construction with optional IP68 protection allows underground or flooded installations, making it ideal for challenging industrial environments.
Configuration and communication are handled via the RS-485 interface with Modbus RTU protocol, enabling remote setup, diagnostics, and integration with automation systems. The flowmeter can be easily programmed for empty-pipe detection, low-flow alarms, or event recording. It also supports external visualization through an optional HMI panel, allowing real-time monitoring and configuration.
The Aplisens Electromagnetic Flowmeter PEM-500 Series, distributed by Dubai Sensor, combines reliability, accuracy, and flexibility, meeting the high standards demanded by industrial users across the UAE and MENA region.
Key Features & Benefits
- Electromagnetic measurement – no moving parts, low maintenance
- Bidirectional flow measurement (total and instantaneous flow)
- High accuracy ± 0.5 % of reading (optional ± 0.2 %)
- Suitable for conductive liquids (≥ 5 µS/cm)
- Output signals: 4–20 mA, pulse, or frequency output
- Digital communication via Modbus RTU / RS-485
- Configurable alarms for low flow and empty pipe
- Compact and robust design with IP67 or optional IP68 protection
- Optional junction box (PP-PEM) and remote HMI panel
- Versions for installation without straight pipe sections (CP version)
- Wide pressure range up to 4 MPa and temperature up to 130 °C (WT version)
- Compatible with potable water systems (PZH version)
Technical Specifications – Aplisens Electromagnetic Flowmeter PEM-500 Series
| Parameter | Specification |
| Nominal Sizes | DN 10 – 300 / ANSI 0.5″ – 12″ |
| Maximum Static Pressure | 1.6 MPa / 2.5 MPa / 4 MPa |
| Accuracy | ± 0.5 % of reading (optional ± 0.2 %) |
| Minimum Conductivity | 5 µS/cm |
| Flow Direction | Bidirectional |
| Analog Output | 4–20 mA (active/passive) |
| Pulse / Frequency Output | 0.1–2000 Hz (frequency), ≤ 500 Hz (pulse) |
| Digital Communication | Modbus RTU / RS-485 (galvanic isolation) |
| Power Supply | 90–260 V AC / 10–36 V DC |
| Power Consumption | 15 VA (AC) / 15 W (DC) |
| Ingress Protection | IP 67 / IP 68 (special version) |
| Ambient Temperature | −20 … +60 °C |
| Liner Temperature Range | Hard rubber: −5 … 90 °C; PTFE: −25 … 90 °C; PFA: −10 … 90 °C |
| Electrodes Material | 316L / Hastelloy / Tantalum |
| Liner Material | Hard rubber, PTFE, PFA |
| Casing / Flanges | Carbon steel (painted) / optional SS 304 |
| Process Connection | Flanged (DIN or ANSI) |
| Ambient Protection Accessories | Grounding rings (stainless steel) |
| Weight | Control unit ≈ 0.5 kg + sensor (depends on DN) |
Standards & Certifications
- Factory calibration according to PN-EN 29104:2003
- PZH certificate – approval for potable water applications (PTFE lining)
- Optional SIL-compliant configurations available on request
- Designed and manufactured in compliance with industrial instrumentation standards
Applications & Industries
- Water and wastewater treatment plants
- Chemical and petrochemical process systems
- Food and beverage manufacturing lines
- Thermal energy and district heating networks
- Suitable for underground or flooded installations (IP68 version)
- Widely used across industrial sites in the UAE / MENA region
Installation, Commissioning & Maintenance
The PEM-500 Series flowmeter is flanged for direct pipeline installation. For most configurations, a 5 × DN upstream and 3 × DN downstream straight pipe length is recommended, except for the CP version, which allows installation without straight sections.
Electrical connections are factory-terminated for convenience, ensuring safe and reliable operation. Optional PP-PEM junction boxes (IP67) simplify wiring in the field. The meter requires no routine recalibration due to its non-mechanical measuring principle, and the optional remote HMI panel facilitates configuration, diagnostics, and real-time flow monitoring.
Why Choose Aplisens Electromagnetic Flowmeter PEM-500 Series
The PEM-500 Series embodies Aplisens’ commitment to precision and dependability in flow measurement. Its electromagnetic technology ensures high accuracy, stable readings, and zero mechanical wear, making it a long-lasting solution for industrial automation.
Ordering Guide
To order the Aplisens Electromagnetic Flowmeter PEM-500 Series, specify:
- Nominal diameter (DN 10–300)
- Electrode material (316L / Hastelloy / Tantalum)
- Liner material (Hard rubber / PTFE / PFA)
- Power supply (90–260 V AC / 10–36 V DC)
- Accuracy class (0.5 % / 0.2 %)
- Special version or accessory (IP68, HMI panel, PP-PEM junction box, WT, CP, 304, PZH)
- Pressure rating (PN16 / ANSI 150)